The Criteria Council has approved HI 2.0. For the first time, climate impact expressed as CO₂e is used as a common metric for both fixed interior elements and furniture within Hållbar Interiör. At the same time, a climate performance requirement is introduced for fixed interior elements through a threshold value in Criterion 4.
For organisations using Hållbar Interiör, this represents a shift from assessing preservation and reuse through percentages, weights and surface areas to assessing the actual climate impact of changes made within a space.
From Preservation Rates to Climate Impact
In HI 1.0, preservation, long-term use and reuse were encouraged through criteria based on factors such as age, proportion of replaced surface area and proportion of reused furniture.
For fixed interior elements, the assessment focused on how much of floors, ceilings, walls, doors and other building elements had been retained or replaced during a given period. For furniture and loose furnishings, weight and percentage-based calculations were used to determine the proportion meeting the criteria.
This provided an important framework for promoting circular resource use, but it also made it difficult to compare the climate impact of different measures and product categories. For example, obtaining reliable weight data for furniture in already furnished premises was often challenging.
In HI 2.0, the point of departure is instead climate impact expressed in CO₂e.
A Common Metric for Fixed Interior Elements and Furniture
In HI 2.0, climate impact is used as a common metric for both Criterion 4 Fixed Interior Elements and Criterion 5 Furniture and Loose Furnishings.
For fixed interior elements, climate impact is calculated for changes involving floors, ceilings, walls, doors and glazed partitions, fixed joinery, sanitary spaces, fixed lighting and white goods.
For furniture and loose furnishings, climate impact is calculated for all furniture within the scope of the certification. The assessment is based on climate impact in kg CO₂e rather than weight or number of items.
According to Derek Diener, member of the HI Criteria Council and active in research and development at RISE with a focus on life cycle management and circular transition, this is the most significant change in the new version:
“When HI 1.0 was developed, the assessment was based on qualitative questions and established principles for reuse, preservation and resource efficiency. With HI 2.0, Hållbar Interiör takes the next step by measuring climate impact in CO₂e. This makes it possible to compare different solutions based on their actual climate impact and provides a more quantitative basis for assessment.”
Assessing both furniture and fixed interior elements using the same climate metric also provides, according to Derek, a more coherent picture of the climate impact of an interior environment.

Derek Diener, PhD, Life Cycle Management, senior researcher RISE
A New Climate Requirement for Fixed Interior Elements
Another important feature of HI 2.0 is that Criterion 4 Fixed Interior Elements now includes a threshold value. To meet the criterion, the climate impact of a facility’s fixed interior elements must not exceed 22.6 kg CO₂e/m² of lettable floor area (LOA).
The threshold value was developed using climate calculations from 24 tenant improvement projects carried out by Castellum during 2025. The dataset was adapted to correspond with Hållbar Interiör’s system boundary for fixed interior elements and analysed to establish a level that is ambitious while still achievable through preservation, reuse and resource-efficient fit-outs.
This means that HI 2.0 not only measures climate impact but also introduces a concrete climate performance requirement for fixed interior elements.
Focus on Results Rather Than Methods
The new threshold value is designed as a performance requirement. Hållbar Interiör defines the result that must be achieved but does not prescribe exactly how a project must achieve it.
A space can therefore meet the requirement through different strategies, such as a high degree of preservation, reuse of existing building elements, careful adaptation, low-carbon material choices, or by reducing the extent of replacement and new installations.
What these approaches have in common is that they contribute to reducing the climate impact of the space’s fixed interior elements.
HI 2.0 Takes Effect in January 2027
HI 2.0 enters into force on 8 January 2027. The criteria document is already available for download from the Hållbar Interiör website.
Verifications initiated before 8 January 2027 will continue to be carried out according to version 1.0.1.
It is already possible to register interest in certifying a space according to HI 2.0.
For more information or to express interest, please contact RISE.